Step 1.
Move stop switch button (B) forward away from the “STOP”
position.
Step 2.
Pump purge bulb (E) until fuel is visible in the “Clear” fuel
return line.
Step 3.
Press decompression button (D) once.
Step 4.
Lay the unit on a flat, clear area, and pull the recoil starter handle (A) until the engine fires.
Note: If engine does not start after 5 pulls, use Cold Start Procedure.