Step 1.
Stop Switch Move stop switch (A) away from the STOP position.
Step 2.
Move choke (B) to Cold Start (closed) position
Step 3.
Pump purge bulb (C) until fuel is visible and flows freely in the clear fuel tank return line. Pump bulb an additional four or five times.
Step 4.
Lay the unit on a flat, clear area. Grip the support handle securely with one hand, and pull the recoil starter handle (D) until engine fires (or 5 pulls maximum).
Step 5.
After engine fires (or 5 pulls), move choke (B) to the RUN (open) position. Restart engine if necessary and allow unit to warm up at idle for several minutes.
Note: If engine does not start with choke in “RUN” position after 5 pulls, repeat instructions 2 - 5
Step 6.
After engine warm-up, grip the throttle handle and support handle. Depress the throttle trigger lockout (E), and gradually depress throttle trigger (F) to increase engine RPM to operating speed.