1

Recoil starter: Use short pulls - only 1/2 - 2/3 of rope length for starting. Do not allow the rope to snap back in. Always hold the unit firmly

2

PB-760 LN H Move throttle position lever (A) to IDLE DETENT position

3

PB-760 LN T Slide Throttle Position / Stop Switch Button (A) back to IDLE position.

4

PB-760 LN H and T Move choke (C) up to COLD START ( ) position.

5

Pump purge bulb (D) until fuel is visible. Pump bulb an additional 4 or 5 times.

6

Pull recoil starter handle (E) until engine fires, or a maximum of 5 pulls.

7

After engine fires (or 5 pulls), move choke lever back to RUN ( ) position, then pull starter handle/rope until engine starts and runs. Allow unit to warm up at idle for several minutes.

8

Note: If engine does not start with choke in RUN position after 5 pulls, move choke to COLD START ( ) position, and repeat steps 4 & 5.

9

Allow engine to warm up for several minutes before use.

After engine warm-up, move throttle lever gradually to increase engine RPM to desired operating speed.