Never perform maintenance or assembly procedures with engine running or serious personal injury may result.
1
Assemble clamps (A) onto both ends of flexible pipe (B).
2
Insert the anti-static wire through the flexible pipe.
3
Assemble swivel pipe (C) into flexible pipe (B).
4
Assemble flexible pipe (B) to elbow (D) on blower and tighten clamps (A).
5
Note: A light lubricant may be used to ease assembly of flexible pipe to blower elbow.
6
Loosen knob (E) completely and expand stick handle clamp. Align wire (G) in handle with grounding strip on swivel pipe (C).
7
Slide stick handle onto swivel pipe (C). Stick handle (F) should be angled away from operator.
8
Position stick handle (F) for comfortable operation. Tighten knob (E).
9
Assemble straight pipe (J) onto swivel pipe (C), until you feel light resistance. Hold swivel pipe and turn straight pipe clockwise, engaging positive locking channels, until connection is firm. Do not force connection.
10
Assemble end pipe (K) to straight pipe (J) the same as in step 8.
11
Note: Blower use will eventually loosen pipe connections. Exclusive positive locking system allows pipes to be tightened. If loosening occurs, remove two pipes and install according to steps 8 and 9.